@article{ART000930385},
author={Chinkap Chung and Eun Kyung Choe and 이명희},
title={Real-time Monitoring of Glucose Using a Differential Refractive Index Detector},
journal={Textile Coloration and Finishing },
issn={1229-0033},
year={2004},
volume={16},
number={2},
pages={47-51}
TY - JOUR
AU - Chinkap Chung
AU - Eun Kyung Choe
AU - 이명희
TI - Real-time Monitoring of Glucose Using a Differential Refractive Index Detector
JO - Textile Coloration and Finishing
PY - 2004
VL - 16
IS - 2
PB - The Korean Society Of Dyers And Finishers
SP - 47
EP - 51
SN - 1229-0033
AB - A differential refractive index detector was used for monitoring glucose contents in textile processing solutions. The sensitivity of the device was high enough to measure 0.05% aqueous glucose solution that could not be measured by normal refractive index measurement. The device was set to monitor glucose concentration continuously in real time by measuring differential refractive index and calibrated by standard glucose solutions in a range of 0.1 to 1.0%. The possibility of industrial application of the device was demonstrated by real-time monitoring of glucose concentration in textile processing solutions such as desizing bath and cellulase treatment bath. Both of solutions contained glucose as a major degraded product. The device would be able to control the weight loss of cellulosic fiber during cellulase treatment since the amount of degraded products in a processing bath is proportional to its weight loss.
KW - glucose;real-time monitoring;differential refractive index detector;cellulase treatment;cellulose
DO -
UR -
ER -
Chinkap Chung, Eun Kyung Choe and 이명희. (2004). Real-time Monitoring of Glucose Using a Differential Refractive Index Detector. Textile Coloration and Finishing , 16(2), 47-51.
Chinkap Chung, Eun Kyung Choe and 이명희. 2004, "Real-time Monitoring of Glucose Using a Differential Refractive Index Detector", Textile Coloration and Finishing , vol.16, no.2 pp.47-51.
Chinkap Chung, Eun Kyung Choe, 이명희 "Real-time Monitoring of Glucose Using a Differential Refractive Index Detector" Textile Coloration and Finishing 16.2 pp.47-51 (2004) : 47.
Chinkap Chung, Eun Kyung Choe, 이명희. Real-time Monitoring of Glucose Using a Differential Refractive Index Detector. 2004; 16(2), 47-51.
Chinkap Chung, Eun Kyung Choe and 이명희. "Real-time Monitoring of Glucose Using a Differential Refractive Index Detector" Textile Coloration and Finishing 16, no.2 (2004) : 47-51.
Chinkap Chung; Eun Kyung Choe; 이명희. Real-time Monitoring of Glucose Using a Differential Refractive Index Detector. Textile Coloration and Finishing , 16(2), 47-51.
Chinkap Chung; Eun Kyung Choe; 이명희. Real-time Monitoring of Glucose Using a Differential Refractive Index Detector. Textile Coloration and Finishing . 2004; 16(2) 47-51.
Chinkap Chung, Eun Kyung Choe, 이명희. Real-time Monitoring of Glucose Using a Differential Refractive Index Detector. 2004; 16(2), 47-51.
Chinkap Chung, Eun Kyung Choe and 이명희. "Real-time Monitoring of Glucose Using a Differential Refractive Index Detector" Textile Coloration and Finishing 16, no.2 (2004) : 47-51.