@article{ART003204000},
author={Chi, Ho Sub and Park, Jungmi and Choi, Gyoungjun and Kang, Ku},
title={Rethinking dosimeter assignment for military radiation safety: Focusing on comparative performance of thermoluminescent dosimeters (TLDs) and electronic personal dosimeters (EPDs) under portable x-ray exposure},
journal={Journal of Advances in Military Studies},
issn={2635-5531},
year={2025},
volume={8},
number={1},
pages={37-56},
doi={10.37944/jams.v8i1.273}
TY - JOUR
AU - Chi, Ho Sub
AU - Park, Jungmi
AU - Choi, Gyoungjun
AU - Kang, Ku
TI - Rethinking dosimeter assignment for military radiation safety: Focusing on comparative performance of thermoluminescent dosimeters (TLDs) and electronic personal dosimeters (EPDs) under portable x-ray exposure
JO - Journal of Advances in Military Studies
PY - 2025
VL - 8
IS - 1
PB - Institute of Defense Acquisition Program
SP - 37
EP - 56
SN - 2635-5531
AB - The increasing use of portable X-ray generators in military operations—particularly for explosive detection and counter-terrorism—has highlighted the need for a radiation safety strategy tailored to field-based, low-dose environments. This study evaluates the performance of thermoluminescent dosimeters (TLDs) and electronic personal dosimeters (EPDs) under controlled pulsed X-ray conditions using the XRS-3 generator, focusing on their sensitivity, dose-response characteristics, and operational suitability in military contexts. The results showed that while TLDs exhibited high accuracy in cumulative dose tracking, they failed to detect radiation beyond 3 meters or at low pulse counts. In contrast, EPDs—although they showed some inconsistencies in cumulative dose measurements under low-dose conditions—successfully detected radiation at all distances and pulse settings. Their ability to provide immediate feedback and detect fluctuations in real time makes them more suitable for dynamic radiation monitoring in military field environments. The study provides a solid foundation for revising current military dosimetry protocols in current military radiation safety management practices.
KW - personal dosimeter;thermoluminescent dosimeter (TLD);electronic personal dosimeter (EPD);military radiation safety;portable X-ray generators
DO - 10.37944/jams.v8i1.273
ER -
Chi, Ho Sub, Park, Jungmi, Choi, Gyoungjun and Kang, Ku. (2025). Rethinking dosimeter assignment for military radiation safety: Focusing on comparative performance of thermoluminescent dosimeters (TLDs) and electronic personal dosimeters (EPDs) under portable x-ray exposure. Journal of Advances in Military Studies, 8(1), 37-56.
Chi, Ho Sub, Park, Jungmi, Choi, Gyoungjun and Kang, Ku. 2025, "Rethinking dosimeter assignment for military radiation safety: Focusing on comparative performance of thermoluminescent dosimeters (TLDs) and electronic personal dosimeters (EPDs) under portable x-ray exposure", Journal of Advances in Military Studies, vol.8, no.1 pp.37-56. Available from: doi:10.37944/jams.v8i1.273
Chi, Ho Sub, Park, Jungmi, Choi, Gyoungjun, Kang, Ku "Rethinking dosimeter assignment for military radiation safety: Focusing on comparative performance of thermoluminescent dosimeters (TLDs) and electronic personal dosimeters (EPDs) under portable x-ray exposure" Journal of Advances in Military Studies 8.1 pp.37-56 (2025) : 37.
Chi, Ho Sub, Park, Jungmi, Choi, Gyoungjun, Kang, Ku. Rethinking dosimeter assignment for military radiation safety: Focusing on comparative performance of thermoluminescent dosimeters (TLDs) and electronic personal dosimeters (EPDs) under portable x-ray exposure. 2025; 8(1), 37-56. Available from: doi:10.37944/jams.v8i1.273
Chi, Ho Sub, Park, Jungmi, Choi, Gyoungjun and Kang, Ku. "Rethinking dosimeter assignment for military radiation safety: Focusing on comparative performance of thermoluminescent dosimeters (TLDs) and electronic personal dosimeters (EPDs) under portable x-ray exposure" Journal of Advances in Military Studies 8, no.1 (2025) : 37-56.doi: 10.37944/jams.v8i1.273
Chi, Ho Sub; Park, Jungmi; Choi, Gyoungjun; Kang, Ku. Rethinking dosimeter assignment for military radiation safety: Focusing on comparative performance of thermoluminescent dosimeters (TLDs) and electronic personal dosimeters (EPDs) under portable x-ray exposure. Journal of Advances in Military Studies, 8(1), 37-56. doi: 10.37944/jams.v8i1.273
Chi, Ho Sub; Park, Jungmi; Choi, Gyoungjun; Kang, Ku. Rethinking dosimeter assignment for military radiation safety: Focusing on comparative performance of thermoluminescent dosimeters (TLDs) and electronic personal dosimeters (EPDs) under portable x-ray exposure. Journal of Advances in Military Studies. 2025; 8(1) 37-56. doi: 10.37944/jams.v8i1.273
Chi, Ho Sub, Park, Jungmi, Choi, Gyoungjun, Kang, Ku. Rethinking dosimeter assignment for military radiation safety: Focusing on comparative performance of thermoluminescent dosimeters (TLDs) and electronic personal dosimeters (EPDs) under portable x-ray exposure. 2025; 8(1), 37-56. Available from: doi:10.37944/jams.v8i1.273
Chi, Ho Sub, Park, Jungmi, Choi, Gyoungjun and Kang, Ku. "Rethinking dosimeter assignment for military radiation safety: Focusing on comparative performance of thermoluminescent dosimeters (TLDs) and electronic personal dosimeters (EPDs) under portable x-ray exposure" Journal of Advances in Military Studies 8, no.1 (2025) : 37-56.doi: 10.37944/jams.v8i1.273