@article{ART001499984},
author={Seong Yeol KIm and Je-Hoon Lee and 안승헌},
title={The Clinical Application of modified Emory Functional Ambulation Profile for Chronic Stroke Patients},
journal={Journal of the Korean Society of Physical Medicine},
issn={1975-311X},
year={2010},
volume={5},
number={4},
pages={655-666}
TY - JOUR
AU - Seong Yeol KIm
AU - Je-Hoon Lee
AU - 안승헌
TI - The Clinical Application of modified Emory Functional Ambulation Profile for Chronic Stroke Patients
JO - Journal of the Korean Society of Physical Medicine
PY - 2010
VL - 5
IS - 4
PB - The Korean Society of Physical Medicine
SP - 655
EP - 666
SN - 1975-311X
AB - Purpose:The examine the reliability and validity of the modified Emory Functional Ambulation Profile(mEFAP) for assessing gait function in chronic stroke patients.
Methods:A total of 45 stroke patients, who had a stroke more than 6 months, participated in the study. Reliability was determined by Intra-class Correlation Coefficient(ICC3,1), including Bland and Altman method (Standard Error of Measurement: SEM, Small Real Differences: SRD). Validity was examined by correlating results to the gait ability(mEFAP, Modified Motor Assessment Scale-Gait(MMAS-G), Scandinavian Stroke Scale- Gait(SSS-G), Functional Ambulation Category(FAC), 10m Waking Test(10m WT)), and Fugl Meyer-Lower/ Extremity(FM-L/E), Berg Balance Scale(BBS).
Results:Inter-rater reliability for the total mEFAP was High(ICC2,1=.998), and absolute reliability were excellent (SEM: 1.75, SRD: 4.85). Subjects without assistance factor performed better on all tests than did subjects who had stroke. There were significant correlations between the mEFAP and MMAS-G, SSS-G, FAC(r=-.66∼-.79), 10 m WT(r=-.86), and FM-L/E, BBS(r=-.72∼-.78), indicating good validity. Increased times on the mEFAP correlated with poor performance on the gait ability, motor function of lower extremity, BBS and slow gait speeds on the 10 m WT in stroke patients.
Conclusion:The mEFAP can be administered easily and comprehensively. It is a reliable gait assessment tool for patients with stroke and correlated with known of function, the mEFAP may be a clinically useful measure of ambulation.
KW - Balance;Gait;Modified Emory Functional Ambulation Profile;Stroke
DO -
UR -
ER -
Seong Yeol KIm, Je-Hoon Lee and 안승헌. (2010). The Clinical Application of modified Emory Functional Ambulation Profile for Chronic Stroke Patients. Journal of the Korean Society of Physical Medicine, 5(4), 655-666.
Seong Yeol KIm, Je-Hoon Lee and 안승헌. 2010, "The Clinical Application of modified Emory Functional Ambulation Profile for Chronic Stroke Patients", Journal of the Korean Society of Physical Medicine, vol.5, no.4 pp.655-666.
Seong Yeol KIm, Je-Hoon Lee, 안승헌 "The Clinical Application of modified Emory Functional Ambulation Profile for Chronic Stroke Patients" Journal of the Korean Society of Physical Medicine 5.4 pp.655-666 (2010) : 655.
Seong Yeol KIm, Je-Hoon Lee, 안승헌. The Clinical Application of modified Emory Functional Ambulation Profile for Chronic Stroke Patients. 2010; 5(4), 655-666.
Seong Yeol KIm, Je-Hoon Lee and 안승헌. "The Clinical Application of modified Emory Functional Ambulation Profile for Chronic Stroke Patients" Journal of the Korean Society of Physical Medicine 5, no.4 (2010) : 655-666.
Seong Yeol KIm; Je-Hoon Lee; 안승헌. The Clinical Application of modified Emory Functional Ambulation Profile for Chronic Stroke Patients. Journal of the Korean Society of Physical Medicine, 5(4), 655-666.
Seong Yeol KIm; Je-Hoon Lee; 안승헌. The Clinical Application of modified Emory Functional Ambulation Profile for Chronic Stroke Patients. Journal of the Korean Society of Physical Medicine. 2010; 5(4) 655-666.
Seong Yeol KIm, Je-Hoon Lee, 안승헌. The Clinical Application of modified Emory Functional Ambulation Profile for Chronic Stroke Patients. 2010; 5(4), 655-666.
Seong Yeol KIm, Je-Hoon Lee and 안승헌. "The Clinical Application of modified Emory Functional Ambulation Profile for Chronic Stroke Patients" Journal of the Korean Society of Physical Medicine 5, no.4 (2010) : 655-666.