@article{ART001857105},
author={Soung Chul Lee},
title={Ventilation Characteristics of Filtration Basin in Water Treatment Plant using 3-D CFD Simulation},
journal={Crisisonomy},
issn={2466-1198},
year={2014},
volume={10},
number={2},
pages={265-272}
TY - JOUR
AU - Soung Chul Lee
TI - Ventilation Characteristics of Filtration Basin in Water Treatment Plant using 3-D CFD Simulation
JO - Crisisonomy
PY - 2014
VL - 10
IS - 2
PB - Crisis and Emergency Management: Theory and Praxis
SP - 265
EP - 272
SN - 2466-1198
AB - In this paper, the ventilation characteristics of a filter basin of the purification plant were investigated for different windows size and the locations by numerical simulation. It has been found that the maximum concentration of chlorine gas in the filter basin with original windows was predicted about 0.13ppm. It means that an additional required amount of ventilation is needed to maintain good indoor air quality. For the filter basin with double sized windows and relocations, the maximum concentration of chlorine gas was predicted 0.11ppm. It is known that the window size and its locations in a filter basin of the purification plant are important factors to reduce the concentration of chlorine gas in the indoor.
KW - filtration basin;water treatment plant;ventilation characteristic;CFD.
DO -
UR -
ER -
Soung Chul Lee. (2014). Ventilation Characteristics of Filtration Basin in Water Treatment Plant using 3-D CFD Simulation. Crisisonomy, 10(2), 265-272.
Soung Chul Lee. 2014, "Ventilation Characteristics of Filtration Basin in Water Treatment Plant using 3-D CFD Simulation", Crisisonomy, vol.10, no.2 pp.265-272.
Soung Chul Lee "Ventilation Characteristics of Filtration Basin in Water Treatment Plant using 3-D CFD Simulation" Crisisonomy 10.2 pp.265-272 (2014) : 265.
Soung Chul Lee. Ventilation Characteristics of Filtration Basin in Water Treatment Plant using 3-D CFD Simulation. 2014; 10(2), 265-272.
Soung Chul Lee. "Ventilation Characteristics of Filtration Basin in Water Treatment Plant using 3-D CFD Simulation" Crisisonomy 10, no.2 (2014) : 265-272.
Soung Chul Lee. Ventilation Characteristics of Filtration Basin in Water Treatment Plant using 3-D CFD Simulation. Crisisonomy, 10(2), 265-272.
Soung Chul Lee. Ventilation Characteristics of Filtration Basin in Water Treatment Plant using 3-D CFD Simulation. Crisisonomy. 2014; 10(2) 265-272.
Soung Chul Lee. Ventilation Characteristics of Filtration Basin in Water Treatment Plant using 3-D CFD Simulation. 2014; 10(2), 265-272.
Soung Chul Lee. "Ventilation Characteristics of Filtration Basin in Water Treatment Plant using 3-D CFD Simulation" Crisisonomy 10, no.2 (2014) : 265-272.