@article{ART001433822},
author={KIM KYUNGHO},
title={A study for measurement of radial artery oxygen saturation system using photoelectric plenthysmography},
journal={Journal of The Korea Society of Computer and Information},
issn={1598-849X},
year={2010},
volume={15},
number={3},
pages={11-18}
TY - JOUR
AU - KIM KYUNGHO
TI - A study for measurement of radial artery oxygen saturation system using photoelectric plenthysmography
JO - Journal of The Korea Society of Computer and Information
PY - 2010
VL - 15
IS - 3
PB - The Korean Society Of Computer And Information
SP - 11
EP - 18
SN - 1598-849X
AB - In this study, the pulse of radial artery and oxygen saturation are detected using photoelectric plethysmograph method. Using our device designed reflection type, we can detect the reflected light by radial artery and by switching circuit, we can also separate to 625nm band signal and 940nm band signals. The separated signals are converted as a pulse data by the pulse signal processing circuit. In this study, the reflection type of oxygen saturation calculation method is applied instead of the transmission type because of the reflection type sensor is used to measure the radial artery. As a result, we can detect about 97% accuracy of the oxygen saturation compare with the conventional method. For the accurate signals, the wrist band with sensor was designed and fixed on the radial artery. As a result, this wrist band type sensor was applicable to prevent position errors from motion artifact and could increase the accuracy during the measuring.
KW - radial artery;photoelectric plenthysmography;oxygen saturation
DO -
UR -
ER -
KIM KYUNGHO. (2010). A study for measurement of radial artery oxygen saturation system using photoelectric plenthysmography. Journal of The Korea Society of Computer and Information, 15(3), 11-18.
KIM KYUNGHO. 2010, "A study for measurement of radial artery oxygen saturation system using photoelectric plenthysmography", Journal of The Korea Society of Computer and Information, vol.15, no.3 pp.11-18.
KIM KYUNGHO "A study for measurement of radial artery oxygen saturation system using photoelectric plenthysmography" Journal of The Korea Society of Computer and Information 15.3 pp.11-18 (2010) : 11.
KIM KYUNGHO. A study for measurement of radial artery oxygen saturation system using photoelectric plenthysmography. 2010; 15(3), 11-18.
KIM KYUNGHO. "A study for measurement of radial artery oxygen saturation system using photoelectric plenthysmography" Journal of The Korea Society of Computer and Information 15, no.3 (2010) : 11-18.
KIM KYUNGHO. A study for measurement of radial artery oxygen saturation system using photoelectric plenthysmography. Journal of The Korea Society of Computer and Information, 15(3), 11-18.
KIM KYUNGHO. A study for measurement of radial artery oxygen saturation system using photoelectric plenthysmography. Journal of The Korea Society of Computer and Information. 2010; 15(3) 11-18.
KIM KYUNGHO. A study for measurement of radial artery oxygen saturation system using photoelectric plenthysmography. 2010; 15(3), 11-18.
KIM KYUNGHO. "A study for measurement of radial artery oxygen saturation system using photoelectric plenthysmography" Journal of The Korea Society of Computer and Information 15, no.3 (2010) : 11-18.