본문 바로가기
  • Home

A Study on Inversion at Leeward Side of High-rise Building in Winter

  • Journal of Environmental Impact Assessment
  • Abbr : J EIA
  • 2010, 19(6), pp.583-590
  • Publisher : Korean Society Of Environmental Impact Assessment
  • Research Area : Engineering > Environmental Engineering

정해연 1 Kyoo-seock Lee 1 김문성 1 오성남 1

1성균관대학교

Accredited

ABSTRACT

To determine nocturnal inversion characteristics at the leeward side of high-rise building, air temperature data were observed at 10 minute interval from February 22, 2010 to April 15, 2010. The observed data were compared, analyzed and examined to illustrate air temperature differences between the roof (XAR) and surface (XAG) of X apartment. The wind speed, wind direction and precipitation data were also observed at XAR and YJL (Yangjae Stream) sites at the same time. After the analysis, the maximum nocturnal inversion was observed by 4.0˚C at 3:40, 3:50, 4:10 on February 24th 2010, at that time the weather condition was clear and weak wind. Air temperature inversions at the leeward side of high-rise building were observed on whole day in wintertime and air temperature inversion intensity was also higher than other nearby area (SMG).

Citation status