ABSTRACT

This study was conducted for the establishment of statistical method to determine the representative air quality monitoring station representing long-term ozone trends of Seoul. In this study, hourly ozone concentrations from 2002 to 2011 were used for further analysis. KZ-filter, correlation matrix, cluster analysis, and Kriging method were applied to select the representative station. The analysis based on correlation matrix found that long-term trend of ozone concentrations measured at Sinjung, Sadang, and Bun-dong showed a high correlation. The cluster analysis found that the former three stations belonged to the same cluster. The analysis based on Kriging method also showed that the former three stations were highly correlated with other stations in spatial distribution. Considering these results and the highest correlation coefficient of Sinjung station, the Sinjung station was the most suitable as the representative station used to understand the long-term ozone trend of Seoul. This result could be applied to understand long-term trend of other pollutants. Furthermore, this result can also be used to assess the appropriacy of spatial distribution of national air quality monitoring stations.