@article{ART002519778},
author={Lim Geon-Tae and Lim, Sang Ho},
title={A Study on Seismic Protection Equipment for Fire Pipes Installed on Buildings},
journal={Industry Promotion Research},
issn={2466-1139},
year={2019},
volume={4},
number={1},
pages={1-9},
doi={10.21186/IPR.2019.4.1.001}
TY - JOUR
AU - Lim Geon-Tae
AU - Lim, Sang Ho
TI - A Study on Seismic Protection Equipment for Fire Pipes Installed on Buildings
JO - Industry Promotion Research
PY - 2019
VL - 4
IS - 1
PB - Industrial Promotion Institute
SP - 1
EP - 9
SN - 2466-1139
AB - This study is a technology related to a seismic protection device for a fire pipe for installation in a building such as an apartment or a building. The fire pipe is fixed to the base panel by fastening bolts so as to flow left and right. The present invention relates to an earthquake-resistant apparatus for a fire-extinguishing piping, which is capable of minimizing damages caused by an earthquake in order to prevent damages and breakage of a fire-extinguishing pipe by mitigating earthquakes, vibrations, It is connected to an insert plate embedded in concrete or ceiling hanger bolts formed at regular intervals on the ceiling to keep the piping constant from the ceiling and to keep the horizontal condition of the piping always constant so that the piping relaxes or sags And to effectively prevent damage to the piping. The can get.
KW - Fire Piping;Seismic restraint;Cushioning;Earthquake Damage;Buildings
DO - 10.21186/IPR.2019.4.1.001
ER -
Lim Geon-Tae and Lim, Sang Ho. (2019). A Study on Seismic Protection Equipment for Fire Pipes Installed on Buildings. Industry Promotion Research, 4(1), 1-9.
Lim Geon-Tae and Lim, Sang Ho. 2019, "A Study on Seismic Protection Equipment for Fire Pipes Installed on Buildings", Industry Promotion Research, vol.4, no.1 pp.1-9. Available from: doi:10.21186/IPR.2019.4.1.001
Lim Geon-Tae, Lim, Sang Ho "A Study on Seismic Protection Equipment for Fire Pipes Installed on Buildings" Industry Promotion Research 4.1 pp.1-9 (2019) : 1.
Lim Geon-Tae, Lim, Sang Ho. A Study on Seismic Protection Equipment for Fire Pipes Installed on Buildings. 2019; 4(1), 1-9. Available from: doi:10.21186/IPR.2019.4.1.001
Lim Geon-Tae and Lim, Sang Ho. "A Study on Seismic Protection Equipment for Fire Pipes Installed on Buildings" Industry Promotion Research 4, no.1 (2019) : 1-9.doi: 10.21186/IPR.2019.4.1.001
Lim Geon-Tae; Lim, Sang Ho. A Study on Seismic Protection Equipment for Fire Pipes Installed on Buildings. Industry Promotion Research, 4(1), 1-9. doi: 10.21186/IPR.2019.4.1.001
Lim Geon-Tae; Lim, Sang Ho. A Study on Seismic Protection Equipment for Fire Pipes Installed on Buildings. Industry Promotion Research. 2019; 4(1) 1-9. doi: 10.21186/IPR.2019.4.1.001
Lim Geon-Tae, Lim, Sang Ho. A Study on Seismic Protection Equipment for Fire Pipes Installed on Buildings. 2019; 4(1), 1-9. Available from: doi:10.21186/IPR.2019.4.1.001
Lim Geon-Tae and Lim, Sang Ho. "A Study on Seismic Protection Equipment for Fire Pipes Installed on Buildings" Industry Promotion Research 4, no.1 (2019) : 1-9.doi: 10.21186/IPR.2019.4.1.001