@article{ART001929529},
author={Seokhyang Cho and Cho Seung Ho},
title={Implementation of a Respiration Measurement System Based on a Nonrestraint Approach},
journal={Journal of The Korea Society of Computer and Information},
issn={1598-849X},
year={2014},
volume={19},
number={11},
pages={33-41}
TY - JOUR
AU - Seokhyang Cho
AU - Cho Seung Ho
TI - Implementation of a Respiration Measurement System Based on a Nonrestraint Approach
JO - Journal of The Korea Society of Computer and Information
PY - 2014
VL - 19
IS - 11
PB - The Korean Society Of Computer And Information
SP - 33
EP - 41
SN - 1598-849X
AB - In this paper, we implemented a system to measure respiration rate with nonrestraint sensorscomfortable for people to do their everyday life. The proposed system consists of a pad covered with aPiezoelectric sensor, a respiration measuring device able to send the signal data after amplifying andfiltering the source signals to the viewer, a viewer providing sensor data visualization and implementingthe respiration measuring algorithm. The algorithm is based on a breathing cycle with the local peak pointsextracted from threshold on sensor data. Respiration measurements on 3 subjects were performed bychanging moving averages and thresholds. The proposed system showed less than 5% error rate when proper moving averages are N=50 ∼ 60 and a range of thresholds is 800 ∼ 1300. The system willcontribute to preventing suffocation during sleep for infants and the elderly living alone.
KW - Respiration;Nonrestraint method;Piezoelectric sensor;Signal processing;u-healthcare
DO -
UR -
ER -
Seokhyang Cho and Cho Seung Ho. (2014). Implementation of a Respiration Measurement System Based on a Nonrestraint Approach. Journal of The Korea Society of Computer and Information, 19(11), 33-41.
Seokhyang Cho and Cho Seung Ho. 2014, "Implementation of a Respiration Measurement System Based on a Nonrestraint Approach", Journal of The Korea Society of Computer and Information, vol.19, no.11 pp.33-41.
Seokhyang Cho, Cho Seung Ho "Implementation of a Respiration Measurement System Based on a Nonrestraint Approach" Journal of The Korea Society of Computer and Information 19.11 pp.33-41 (2014) : 33.
Seokhyang Cho, Cho Seung Ho. Implementation of a Respiration Measurement System Based on a Nonrestraint Approach. 2014; 19(11), 33-41.
Seokhyang Cho and Cho Seung Ho. "Implementation of a Respiration Measurement System Based on a Nonrestraint Approach" Journal of The Korea Society of Computer and Information 19, no.11 (2014) : 33-41.
Seokhyang Cho; Cho Seung Ho. Implementation of a Respiration Measurement System Based on a Nonrestraint Approach. Journal of The Korea Society of Computer and Information, 19(11), 33-41.
Seokhyang Cho; Cho Seung Ho. Implementation of a Respiration Measurement System Based on a Nonrestraint Approach. Journal of The Korea Society of Computer and Information. 2014; 19(11) 33-41.
Seokhyang Cho, Cho Seung Ho. Implementation of a Respiration Measurement System Based on a Nonrestraint Approach. 2014; 19(11), 33-41.
Seokhyang Cho and Cho Seung Ho. "Implementation of a Respiration Measurement System Based on a Nonrestraint Approach" Journal of The Korea Society of Computer and Information 19, no.11 (2014) : 33-41.