@article{ART002167403},
author={양정규 and Hee Duk Park},
title={Real Time Relative Radiometric Calibration Processing of Short Wave Infra-Red Sensor for Hyper Spectral Imager},
journal={Journal of The Korea Society of Computer and Information},
issn={1598-849X},
year={2016},
volume={21},
number={11},
pages={1-7}
TY - JOUR
AU - 양정규
AU - Hee Duk Park
TI - Real Time Relative Radiometric Calibration Processing of Short Wave Infra-Red Sensor for Hyper Spectral Imager
JO - Journal of The Korea Society of Computer and Information
PY - 2016
VL - 21
IS - 11
PB - The Korean Society Of Computer And Information
SP - 1
EP - 7
SN - 1598-849X
AB - In this paper, we proposed real-time relative radiometric calibration processing method for SWIR(Short Wavelength Infra-Red) sensor using ‘Hyper-Spectral Imager’. Until now domestic research for Hyper-Spectral Imager has been performing with foreign sensor device. So we have been studying hyper spectral sensor device to meet domestic requirement, especially military purpose. To improve detection & identify capability in ‘Hyper-Spectral Imager’, it is necessary to expend sensing wavelength from visual and NIR(Near Infra-Red) to SWIR. We aimed to design real-time processor for SWIR sensor which can control the sensor ROIC(Read-Out IC) and process calibrate the image.
To build Hyper-Spectral sensor device, we will review the SWIR sensor and its signal processing board. And we will analyze relative radiometric calibration processing method and result. We will explain several SWIR sensors, our target sensor and its control method, steps for acquisition of reference images and processing result.
KW - SWIR;hyper-spectral imager;Radiometric Calibration
DO -
UR -
ER -
양정규 and Hee Duk Park. (2016). Real Time Relative Radiometric Calibration Processing of Short Wave Infra-Red Sensor for Hyper Spectral Imager. Journal of The Korea Society of Computer and Information, 21(11), 1-7.
양정규 and Hee Duk Park. 2016, "Real Time Relative Radiometric Calibration Processing of Short Wave Infra-Red Sensor for Hyper Spectral Imager", Journal of The Korea Society of Computer and Information, vol.21, no.11 pp.1-7.
양정규, Hee Duk Park "Real Time Relative Radiometric Calibration Processing of Short Wave Infra-Red Sensor for Hyper Spectral Imager" Journal of The Korea Society of Computer and Information 21.11 pp.1-7 (2016) : 1.
양정규, Hee Duk Park. Real Time Relative Radiometric Calibration Processing of Short Wave Infra-Red Sensor for Hyper Spectral Imager. 2016; 21(11), 1-7.
양정규 and Hee Duk Park. "Real Time Relative Radiometric Calibration Processing of Short Wave Infra-Red Sensor for Hyper Spectral Imager" Journal of The Korea Society of Computer and Information 21, no.11 (2016) : 1-7.
양정규; Hee Duk Park. Real Time Relative Radiometric Calibration Processing of Short Wave Infra-Red Sensor for Hyper Spectral Imager. Journal of The Korea Society of Computer and Information, 21(11), 1-7.
양정규; Hee Duk Park. Real Time Relative Radiometric Calibration Processing of Short Wave Infra-Red Sensor for Hyper Spectral Imager. Journal of The Korea Society of Computer and Information. 2016; 21(11) 1-7.
양정규, Hee Duk Park. Real Time Relative Radiometric Calibration Processing of Short Wave Infra-Red Sensor for Hyper Spectral Imager. 2016; 21(11), 1-7.
양정규 and Hee Duk Park. "Real Time Relative Radiometric Calibration Processing of Short Wave Infra-Red Sensor for Hyper Spectral Imager" Journal of The Korea Society of Computer and Information 21, no.11 (2016) : 1-7.