@article{ART002406818},
author={Mi-Suk Choi and Dong-Ha Ji},
title={A study on Measurement and Improvement of Indoor Air Quality in Dental Clinic},
journal={Journal of The Korea Society of Computer and Information},
issn={1598-849X},
year={2018},
volume={23},
number={11},
pages={143-149},
doi={10.9708/jksci.2018.23.11.143}
TY - JOUR
AU - Mi-Suk Choi
AU - Dong-Ha Ji
TI - A study on Measurement and Improvement of Indoor Air Quality in Dental Clinic
JO - Journal of The Korea Society of Computer and Information
PY - 2018
VL - 23
IS - 11
PB - The Korean Society Of Computer And Information
SP - 143
EP - 149
SN - 1598-849X
AB - The purpose of this study is to propose a management method to maintain the pleasant indoor air quality of the dental clinic by measuring and analyzing the indoor air quality of the dental clinic.
The measurement was conducted in two rooms, a lobby where many residents stay in the reception room for waiting for medical treatment, and a VIP room where treatment activities are mainly performed.
Measurement items are Temperature, Humidity, CO2, CO, NO2, CH2O, VOC, PM10 and measurement were taken on April 27, 2018. As a result of analyzing the temperature and humidity of the dental clinic, it was analyzed that the average indoor temperature was maintained at 25℃ and the humidity was kept at around 50%, maintaining proper indoor temperature and humidity environment. CO2 was 855ppm in the VIP Room, which satisfied the maintenance standard. In the case of the lobby, it was analyzed to be 1,160ppm, which exceeded the maintenance standard and it is judged that the carbon dioxide generated by the respiration of the people staying in the lobby is the main reason.
The mean concentration of formaldehyde in the VIP room was analyzed as 436μg/m3, exceeding the maintenance standard, and 2,100μg/m3 for the VOC exceeded the recommended standard. It was analyzed that the concentration was relatively higher due to the use of disinfectant and other drugs.
The mean concentration of PM-10 in the lobby was analyzed as 65μg/m3 and it was analyzed that it satisfied the maintenance standard. To maintain a pleasant indoor air quality in a dental clinic it is necessary to minimize the effects of formaldehyde, VOC, CO2 in the VIP rooms and lobby. For this purpose, the entire ventilation system and air purification system of the dental clinic should be installed. In case of the VIP room, local exhaust ventilation should be installed and workers should wear personal protective equipment.
KW - Indoor air quality;Maintenance standard;Purification system;Personal protective equipment
DO - 10.9708/jksci.2018.23.11.143
ER -
Mi-Suk Choi and Dong-Ha Ji. (2018). A study on Measurement and Improvement of Indoor Air Quality in Dental Clinic. Journal of The Korea Society of Computer and Information, 23(11), 143-149.
Mi-Suk Choi and Dong-Ha Ji. 2018, "A study on Measurement and Improvement of Indoor Air Quality in Dental Clinic", Journal of The Korea Society of Computer and Information, vol.23, no.11 pp.143-149. Available from: doi:10.9708/jksci.2018.23.11.143
Mi-Suk Choi, Dong-Ha Ji "A study on Measurement and Improvement of Indoor Air Quality in Dental Clinic" Journal of The Korea Society of Computer and Information 23.11 pp.143-149 (2018) : 143.
Mi-Suk Choi, Dong-Ha Ji. A study on Measurement and Improvement of Indoor Air Quality in Dental Clinic. 2018; 23(11), 143-149. Available from: doi:10.9708/jksci.2018.23.11.143
Mi-Suk Choi and Dong-Ha Ji. "A study on Measurement and Improvement of Indoor Air Quality in Dental Clinic" Journal of The Korea Society of Computer and Information 23, no.11 (2018) : 143-149.doi: 10.9708/jksci.2018.23.11.143
Mi-Suk Choi; Dong-Ha Ji. A study on Measurement and Improvement of Indoor Air Quality in Dental Clinic. Journal of The Korea Society of Computer and Information, 23(11), 143-149. doi: 10.9708/jksci.2018.23.11.143
Mi-Suk Choi; Dong-Ha Ji. A study on Measurement and Improvement of Indoor Air Quality in Dental Clinic. Journal of The Korea Society of Computer and Information. 2018; 23(11) 143-149. doi: 10.9708/jksci.2018.23.11.143
Mi-Suk Choi, Dong-Ha Ji. A study on Measurement and Improvement of Indoor Air Quality in Dental Clinic. 2018; 23(11), 143-149. Available from: doi:10.9708/jksci.2018.23.11.143
Mi-Suk Choi and Dong-Ha Ji. "A study on Measurement and Improvement of Indoor Air Quality in Dental Clinic" Journal of The Korea Society of Computer and Information 23, no.11 (2018) : 143-149.doi: 10.9708/jksci.2018.23.11.143