본문 바로가기
  • Home

A study on the performance test and acoustic design of interference type noise reduction device for railway noise

  • Journal of Environmental Impact Assessment
  • Abbr : J EIA
  • 2011, 20(6), pp.787-795
  • Publisher : Korean Society Of Environmental Impact Assessment
  • Research Area : Engineering > Environmental Engineering

조준호 1 Hyoin Koh 1

1한국철도기술연구원

Accredited

ABSTRACT

Noise barrier is generally used with welding of joint rail for railway noise reduction in our country. But the noise barrier for high speed railway has weak point in low frequencies about 315Hz band. In this study, For developing of Interference-type Noise Reduction Device(INRD),acoustic analysis were performed using commercial software. For verifying the improvement in the noise reduction, noise measurement before and after installing of INRD were performed in Anechoic Chamber. From these acoustic analysis and noise measurement, it was known that developed INRD has a good noise reduction performance and can be used efficiently with conventional noise barrier.