ABSTRACT

CPR is very important to paramedics, but the chest compression performed while on the move main stretcher is less accurate. The purpose of this study is to find out the difference between performing chest compression on the side of the main stretcher using C-step and on the patient's over the belly in order to increase the effect of CPR on the main object while on the move. As a result of the study, the appropriate depth (t=4.132, p=.000) and speed (t=7.177, p=.000) were shown in the group to which the C-step was applied, and the accuracy was higher (t=6.774, p=.000). In addition, it was found that there were few location defects (t=-5.197, p=.000) and too shallow errors (t=-2.948, p=.008) in the group to which the C-step was applied. In conclusion, mounting a C-step on the main stretcher seems to help improve the quality of chest compression, and it is thought that this will increase the efficiency of chest compression.

Citation status

* References for papers published after 2023 are currently being built.

This paper was written with support from the National Research Foundation of Korea.